Provide more compressed air quality than expected Vimenser VF Series of intelligent filters in the compressed air circulation path design, synchronized with the world’s advanced design level. The Hankison filter element is used to reduce energy consumption and save energy while efficiently removing pollutants.
Provide more compressed air quality than expected Vimenser VF Series of intelligent filters in the compressed air circulation path design, synchronized with the world’s advanced design level. The Hankison filter element is used to reduce energy consumption and save energy while efficiently removing pollutants.
Reduce compression and save operating costs
VF series combines aerodynamics and fluid mechanics, and is designed through precise calculation. It guides compressed air into the filter element along an arc path for filtration, with stronger pollutant removal capacity and smaller pressure drop. For every 0.14kgf/m2 decrease in voltage drop, power input can be reduced by 1%, effectively controlling and reducing overall operating costs.
Intelligent monitoring and remote management
Genius has innovatively developed a new generation ofcompressed air monitoring cloud platform,which canefficiently filter compressed air while establishing a digitavirtual factory to comprehensively monitor, analyze, andpresent the compressed air status of the entire factory. Thecombination of filters and the Internet of Things significantlyreduces manual inspections, ensures the efficiency of filterusage, and effectively avoids the possibility of air quality non-compliance and production shutdown caused by filter failure inair compression stations
9 advantages of VF intelligent filters compared to traditional filters
1. High filtration efficiency, highly accommodating dust volume, and low wind resistance
2. High speed, low eddy current, low flow resistance, and low noise
3. The sensor interface is sufficient, and the pipe strength meets the standard
4. Collect data, record, analyze, and process it, and upload it to the cloud
5. Real time display of air status and alarms
6. Online fault warning, maintenance cycle reminder, and data tracing
7. Overall interconnection of compressed air system
8. Generate workshop diagnostic reports
9. Assist customers in big data analysis
Technical parameter table
Product Model | Treating flow capacity Nm3/min | Interface size | Equipment Weight | Height | Width |
VF-1 | 1.1 | G1/2 | 0.8 | 310 | 104 |
VF-2 | 1.9 | G1 | 1.2 | 380 | 104 |
VF-3 | 3.2 | G1-1/2 | 1.4 | 491 | 138 |
VF-6 | 5.5 | G1-1/2 | 3.8 | 491 | 138 |
VF-8 | 8.1 | G1-1/2 | 4.5 | 691 | 138 |
VF-12 | 12.0 | G2 | 5.5 | 752 | 148 |
VF-16 | 15.7 | G2 | 7.6 | 752 | 148 |
VF-18 | 17.7 | G2-1/2 | 8.8 | 850 | 150 |
VF-22 | 22 | G2-1/2 | 12 | 990 | 150 |
VF-30 | 30 | DN80 | 71 | 1065 | 560 |
VF-40 | 40 | DN100 | 60 | 1260 | 590 |
VF-60 | 60 | DN100 | 75 | 1325 | 650 |
VF-70 | 70 | DN100 | 143 | 1290 | 741 |
VF-90 | 90 | DN150 | 145 | 1300 | 745 |
VF-120 | 120 | DN150 | 115 | 1455 | 790 |
VF-150 | 150 | DN150 | 130 | 1490 | 845 |
VF-180 | 180 | DN200 | 152 | 1560 | 850 |
VF-200 | 200 | DN200 | 188 | 1590 | 900 |
VF-250 | 250 | DN200 | 180 | 1585 | 960 |
VF-300 | 300 | DN250 | 200 | 1685 | 990 |
VF-350 | 350 | DN250 | 220 | 1710 | 1050 |
VF-400 | 400 | DN300 | 260 | 1820 | 1100 |
VF-500 | 500 | DN300 | 280 | 1845 | 1175 |
Minimum inlet pressure | Psig | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 150 | 200 | 250 | 300 |
barg | 1.4 | 2.1 | 2.8 | 4.1 | 5.5 | 6.9 | 8.3 | 10.3 | 13.8 | 17.2 | 20.7 | |
Correction Coefficient | 0.30 | 0.39 | 0.48 | 0.65 | 0.82 | 1.00 | 1.17 | 1.43 | 1.87 | 2.31 | 2.74 | |